L414-1 Control for Pressure and Vacuum Range Adjustable Differential Adjustable Cat. No. Min. Max. Min. Max. List Price 3556 22" 35 Ibs. 4" Vac. at 22” Vac. 25:30 Ibs. 2 Ibs. at 0 Ibs. 3 Ibs. at 35 Ibs. $11.00 Type T414-1 Control for Temperature Range Adjustable Differential Adjustable Cat.No. Min. Max. Min. Max. Tube Length —List Price 3557 —50° —10° OP Be 12° -15° 6 it. $12.50 y : 3557-A Boe —10° ge 3° 12° - 15° 10 ft. 14.00 | 3557-B —20° +20° oF 23° ye .15° 6ft. 12.50 \ 3557-C —20° +20° gg" 1ee=I5° 10 ft. 14.00 \ 3557-D +10° +50? 28° 12° - 15° 6 ft. 12.50 — 3557-E +10° +50° 208° 12°'.15° 10 ft. 14.00 [41] MELCHIOR, ARMSTRONG, DESSAU CO. sia ELECTRIC REFRIGERATION SUPPLIES i kA) Minneapolis-Honeywell Controls for Commercial Refrigeration Temperature, Pressure and Vacuum Service Type L413-1 Combination Control with High Pressure Safety Cut-Out for Pressure and Vacuum Service Range Adjustable Differential Adjustable HLP. Safety Cat. No. Min. Max. Min. Max. Cut-Out Range _ List Price 3557-F 22” 35 Ibs. 4" Vac. at 22”Vac. 25-30 Ibs. 2 lbs. at 0 Ibs. 3 Ibs. at 35 Ibs. 150-180 Ibs. $17.00 This control can also be supplied with high pressure cut-out range of 110-135 Ibs. or 185-220 Ibs. adjust- able within each range on special order. Type T413-1 Combination Temperature Control and High Pressure Safety Cut-Out Range Adjustable Differential Adjustable HP. Safety Tube Min. Max. Min. Max. Cut-Out Range — Length List Price —50° —10° ote? 12°.15° 150-180 Ibs. Git. $18.50 —50° —l0° org? 12° -15° 150-180 Ibs. 10 ft. 20.00 —20° +20° or ge get 150-180 Ibs. 6 ft. 18.50 —20° +20° age 12° -15° 150-180 Ibs. 10 ft. 20.00 +10° +50° 2° 3° 12° -15° 150-180 Ibs. 6 ft. 18.50 \ +10° +50° 2 3? 12° -15° 150-180 Ibs. loft. 20.00 = This control can also be supplied with high pressure cut-out range of 110-135 Ibs. or 185-220 Ibs. adjustable within each range on special order. Type T42-3 Room Thermostat Used on control systems wherein Thermostat controls motor directly within ratings shown below. Can be used with magnetic starter on larger or polyphase motors. Electrical Rating: 8 Amp., 110 V.; 4 Amp., 220 V. Motor Rating: 110-250 V., Single Phase A.C. or D.C. % H.P., R. 1. 4% HP. Range Adjustable Cat. No. Min. Max. Differential List Price 3558-F 40° 80° 2°:63° $13.50 Type 149 Airswitch Used as a control to regulate the temperature in florist cabinets, butcher cases, cooler rooms, and similar applications. Also used as a limit control where it is necessary to prevent dangerously low temperatures, such as in florist cases. Can withstand extreme conditions of temperature and humidity. Equipped with Jock device and differential adjustment. Electrical Rating: 8 Amp. 110 V.; 4 Amp. 220 V. Motor Rating: 110-250 V.; Single Phase A. C. or D.C. % H.P.; R. I. % HP. Range Adjustable Differential Adjustable Cat. No. Min. Max. Min. Max. List Price 3558.G ve 95° 3° 8° $13.00 MERCURY TUBES FOR MINNEAPOLIS-HONEYWELL CONTROLS Minneapolis- Honeywell List Price Cat. No. No. For Types L 413-1, L 414-1, T 413-1, 3558-J H-164-9 T 414-1 Controls $3.20 3558K = C-412.2 For Types T-42-3 Thermostat 3.65, 3558-L C597-4 For Types 149 Airswitch 3.65 [42] MELCHIOR, ARMSTRONG, DESSAU CO. Metco} ELECTRIC REFRIGERATION SUPPLIES 7 EAN No. 855 Mercoid Room Thermostat Mercury Tubes for Mercoid Controls Electrical Rating: 10 Amp. at 110 V., 5 Amp. at 220 V., 3 Amp. at 440 V., either D.C. or : A.C. or D.C. Rating—Amperes A.C. Any Cycle, Motors drawing more cur- Cat, No, Mercoid No. 10V. 220V.. List Price rent are controlled by the use of an automatic 459.0 Fig.2 10 5 $7.00 starting switch, 3559-D Fig. 3 10 5 5.00 ; ’ 3559-E Fig. 9-518 10 5 3.50 Range Adjustable 3559-F Fig. 9-61R 4 2 2.00 Cat. No. Min. Max. Differential —List Price 3559-G Fig. 9-62R 4 2 3.10 25° 60° oe $16.50 65° 90° 2° 16.50 Cat. No. 3559-A is used in Air Conditioning installations and com- pletes circuit at high. List Price 3559-B Thermometer only for above $1.50 FRIEZ CONTROLS FOR AIR CONDITIONING HUMIDISTATS For the automatic control of Relative Humidity in all classes of comfort and industrial applications when used to operate electric solenoid valves, motor-operated valves, damper motors, sprays, relays, heaters, compressors, pumps, fans, etc., and all classes of humidifying and dehumidifying equipment. Use multiple human hair elements and are accurate, sensitive and reliable. Electrical Rating: Maximum Voltage 120 A.C. or D.C.; Maximum amperage 2.5; Maximum V.A. (or Watts) 50. Suitable for low or high voltage. Relative Humidity Range Adjustable 10% to 100%. Differential; 1% above and below setting. Knob and rotating type dial setting. All Friez instruments finished “Satin Silver” Type H/4 Snap acting, single pole, single throw (2-wire), to complete circuit at low. Suitable for use with humidifying equipment and for operation of solenoid valves, thermal type valves and damper-motors, or for 2-wire booster relays where heavy loads have to be handled. Cat. No. 3559-H. List Price $18.00 Type H/5 Snap acting, single pole, single throw—(2-wire), to complete circuit at high. Suitable for use with dehumidifying equipment and for operation of solenoid valves, thermal type valves and damper motors, or for 2-wire booster relays where heavy loads-have-to be handled. Cat. No. 3559-1 List Price $18.00 Type H/6 Snap acting, single pole, double throw (3-wire). As used for “positive” type motor valves or damper-motors and for “Summer-Winter” application by use of Cat. No. 3559-V Summer-Winter Switch. Cat. No. 3559-J List Price $18.00 Type H/7 Same as Cat. No. 3559-J but without snap action. As used for 3-wire system holding-circuit type relay transformer sets, “reversing” type motor valves and dual load relay sets of certain types. Cat. No. 3559-K List Price $17.00 [43 ] ry MELCHIOR, ARMSTRONG, DESSAU co. feo fevectric REFRIGERATION SUPPLIES M15 FRIEZ THERMOSTATS Electrical Rating: Maximum Voltage 120 A.C. or D.C.; Maximum Amperage 5; Maximum V.A. (or Watts) 100. Suitable for low or line voltage. Range 30° F. to 100° F, Adjustable Differential 1° F. Knob and rotating Type dial setting. Type T/4 Single pole, single throw (two-wire), snap acting to complete circuit at low for heat- ing. Standard range 55° F. to 85° F. Cat, No. 3559-L List Price $16.00 Type T/5 Single pole, single throw (two-wire) snap acting to complete circuit at high for cool- ing. Standard range 55° F, to 85° F.. Cat. No. 3559-M List Price $16.00 Type T/6 Single pole, double throw (three-wire), snap acting; (for “positive” motor valves and for “Summer-Winter” application by use of Cat. No. 3559-V Summer-Winter Switch, Standard range 55° F. to 85° F.) Cat. No. 3559-N List Price $16.00 Type T/7 Same as Cat. No. 3559-N but without snap action (for “reversing” motor valves, 3-wire relays, and dual load relay sets of certain types.) Cat. No. 3559-0 List Price $15.00 FRIEZ BOOSTER RELAYS AND RELAY-TRANSFORMER SETS While Humidistats and Thermostats will in themselves give complete control to equipment drawing light loads, relays must be employed for heavy loads, such as where control is required for larger electric motors, pumps, compressors, fans, heating elements, etc. Complete in “knock-out” type boxes with cover. Booster Relays 2-wire common control circuit, single pole, single throw, for use with snap- acting Humidistats and Thermostats. With these relays, control circuit and wiring to instrument remains on line voltage. Type A/AA Load Rating: 110 V., 25 or 60 Cyc, 15 Amps. Non-Inductive; 4 H.P. Inductive. Cat. No. 3559-P List Price $6.55 Type A/AB Load Rating: 220 V., 25 or 60 Cyc., 15 Amps. Non-Induetive, % HP. Inductive. Type A/AA Cat. No. 3559-Q List Price $6.55 Relay Transformer Sets 2-wire separate control circuit operating voltage transformer which is incorporated into set. Single pole, single throw for use with snap-acting Humidistats and Thermostats. With this type control circuit the wiring to instrument becomes low voltage with the consequent added safety, ease and saving in installation. | | Ss a = a AS) is] | Type A/BA | | Load Rating: 110 V., 25 or 60 Cyc.; 15 Amps. Non-Inductive; 4 H.P. Inductive. | Cat. No. 3559-R List Price $13.15 | @ Type A/BB Load Rating: 220 V., 25 or 60 Cyc.; 15 Amps. Non-Inductive; 44 H.P. Inductive. Cat. No. 3559-S List Price $13.15 Type A/BA [44] ry MELCHIOR, ARMSTRONG, DESSAU CO. Metco ELECTRIC REFRIGERATION SUPPLIES 6 Three-Wire Holding Circuit Relay-Transformer Sets Same as Cat. Nos. 3559-R and 3559-S but so interwired as to provide a positively held circuit, thus making independent of vibration or chattering at instrument contacts. Can be used with instruments that have no snap action and represents the best electrical practice. For use with Cat. Nos. 3559-K Humidistat and 3559-0 Thermostat. On these sets, Control circuit and wiring to instrument becomes low voltage. Type A/CA Load Rating: 110 V., 25 or 69 Cyc.; 8 Amps. Non-Inductive; 4% H.P. Inductive. Cat. No. 3559-T List Price $13.90 Type A/CB Load Rating: 220 V., 25 or 60 Cyc.; 8 Amps. Non-Inductive; 4 H.P. Inductive. Cat. No. 3559-U List Price $13.90 Summer-Winter Switches for Friez Humidistats and Thermostats Cat. Nos. 3559-J Humidistat and 3559-N Thermostat are fitted with both “low” and “high” contacts in addition to the “moving” or center contact and by means of the Summer-Winter Switch their operation can be reversed so that whereas the instrument is needed to complete circuit at low humidity or temperature respectively in the winter, a simple movement of the switch can reverse it so that the instrument com- pletes circuit at high humidity or temperature respectively in the summer. Type SW/1 Single pole, double throw, for low voltage or 3 Amps. at 125 V., or 1 Amp. at 250 V. To reverse action of controlling instrument where same is employed on 2-wire control circuits. Cat. No. 3559-V List Price $0.90 Type SW/2 Double pole, double throw, for low voltage or 3 Amps. at 125 V., or 1 Amp. at 250 V. To reverse action of controlling instrument where same is employed on 3-wire control circuits, 3-wire relay-transformer sets, etc., or where used to control two separate 2-wire relays. Cat. No. 3559-W List Price $1.00 Cat. No. 3559-X Flush Wall Mounting Switch Plate (Brass Finish) for above. List Price 25 Pressure Type Water Regulator Regulates the flow of water through the condenser co’ Opens as head pressure rises and closes as it falls. Suitable for use with any refrigerant except ammonia. Penn Type XLI Operates directly from double ply bellows to stem of valve. Self cleaning. Opens at Connections Cat. No. Refrigerant Lbs. Pressure Water Compressor List Price 3556-A Sulphur Dioxide 50 56” F.P.T. 44” S.A.E. $14.00 3556-B Methyl Chloride 85 36 EF P.T. 44” S.A. 14.00 3556-C Freon 100 96" F-P.T. 44" S.A.E. 14.00 Electrimatic Type WRP Packless direct bellows operated construction with high pressure water inlet under seat eliminating counter balancing spring. Corrosion resisting naval bronze body and parts, non-chattering, noiseless in operation, tight closing. Has an adjustable pressure range 50 Ibs. to 185 Ibs. with an operating differential of 15 Ibs. between a tight closed and wide open position. Single Adjustment. Suitable for use with any refrigerant except ammonia. Cat. No. Female Pipe Connection List Price 3557-G 56” $10.00 3557-H 14" 15.00 3557-1 %” 15.00 {45 ] MELCHIOR, ARMSTRONG, DESSAU CO. ELCO| ELECTRIC REFRIGERATION SUPPLIES 15 Electrimatic Type WRB For heavy duty. Constructed of same materials as Type WRP. Seat disc and bead can be replaced without dis- connecting pipe. Has large oversize strainer screen incorporated in cartridge cap. Adjustable pressure range 50 Ibs. to 185 Ibs. with an operating differential of 30 Ibs. Single adjustment. Suitable for use with any refrigerant except ammonia. Cat. No. Female Pipe Connection List Price 3558-N a" $14.00 3558-0 %" 18.00 3558-P 4” 18.00 Electrimatic Combination Water Valve with High Pressure Cut-Out Type WRM Combines the fine qualities of the Type WRB valve with a Mercoid Snap Action Mercury Switch used in the cut-out. Adjustment of the switch is visible and independent of the water valve adjustment. Only one refriger. ant pressure connection necessary. Adjustable pressure range 50 Ibs. to 185 Ibs. Differential 30 lbs. High Pressure Cut-out Range (Adjustable) 150 Ibs. to 275 Ibs, Differential 25 Ibs. to 75 Ibs. Electrical Rating 4 Amp., 290 Volts. Suitable for use with any refrigerant except ammonia. Cat. No. Female Pipe Connections List Price 3559-1 %” $26.00 3559-A-T yy" 29.00 3559-B-I 4” 29.00 3559-C-T 1” 35.00 3559-D-I 14" 35.00 3559-E-T 14" 68.00 3559-F-1 2" 68.00 TWO-TEMPERATURE VALVES Two-temperature Control Valves are used where two or more evaporator temperatures are to be maintained by one condensing unit. They are applicable to dry expansion systems, flooded systems, or a combination of dry and flooded systems with pressure control of the con- densing unit. ‘Two-temperature Control Valves are generally of two types, namely the mechanical or pressure-operated type, and the solenoid or elec- trically operated type. The use of the two-temperature valve is to control the flow of liquid refrigerant to each evaporator, or to control the flow of gas leaving each evaporator. The mechanical type valve is installed in the suction line and maintains the evaporator at pre- determined temperature limits by keeping the refrigerant in the evaporator under corresponding pressure limits. The valve automatically opens at the maximum pressure setting and does not close until the minimum pressure setting is reached. The Solenoid type is usually installed in the liquid line to the evaporator ahead of the thermostatic valve, and is operated by a thermostat controlling the temperature of the evaporator, room or liquid being cooled. The Solenoid remains closed until the thermostat calls for refrigeration and then opens until the thermostat requirements are satisfied. Mueller Two-Temperature Valve PRESSURE OPERATED Adjustments may be made by turning the outside knurled case which raises or lowers the cut-out or cut-in without changing the differential. Differential is not adjustable. STANDARD OPERATING RANGES Adjustable Operating Range Min. Max. Differential Cat. No. Refrigerant Cutout Cut-in = Min, Max. —_List Price 3565 Sulphur Dioxide Olbs. 10lbs. SIbs. 15 Ibs. $15.00 3565-A Methyl Chloride lbs. 25Ibs. SIbs. 15 Ibs. ‘15.00 [46]
Affiliate Disclosure: Survivorpedia.com, owned by Manamize LLC, is a participant in various affiliate advertising programs. We may earn commissions on qualifying purchases made through links on this site at no additional cost to you. Our recommendations are based on thorough research and real-world testing.
survival refrigeration 1935 emergency response food preservation historical public domain triage
Related Guides and Tools
Articles
Interactive Tools
Comments
Leave a Comment
Loading comments...